Monitor and control modules, offering high performance by the VIP communication protocol, can be configured to operate in cause-effect scenario and fire automation can be performed. Contact us to schedule a professional installation and free consultation!
Monitor and control modules, offering high performance by
the VIP communication protocol, can be configured to operate in cause-effect
scenario and fire automation can be performed.
- Compatible with EN 54-17 and EN 54-18
- Optional short circuit isolator models
- LED-indicated activation, fault, and communication status
- Easy mounting with rail system
- 2/1 I/O module with 2 zone monitoring inputs 1 sounder
output option or 2 dry contact monitoring inputs 1 dry contact relay output
option
- 4/2 I/O module with 4 dry contact monitoring inputs 2 dry
contact relay outputs option
Modules are loop-powered and can be programmed to operate in
cause-effect scenarios. External systems can be monitored by switch monitor
inputs and can be controlled by relay outputs within fire automation.
Switch monitor inputs are used for monitoring external dry
switch relay output. Switches have normally open and normally close operate
features. In case of changing of switch position, event type that is detected
by panels can be determined by users.
The module has one relay output with voltage-free, bipolar
contact max. load of 30V DC, 1A . The relay can operate as normally open or
normally close.
The models have SCI, internal short circuit isolator, in case of short circuit events, isolates the line.
Energy Input/Output needs 18V - 30V DC external power supply
and that can be monitored in case of fault event and programmable for
cause-effect scenarios.
Zone monitoring Inputs are used to monitor the conventional
type detectors and manual call points. In case of change of Input status,
events type that are detected by panel can be determined by users.
24V DC 500mA sounder output can be activated within fire
automation as required. 24V DC 500mA sounder output can be arranged according
to event type that is determined by users.
With SCI models, internal short circuit isolator, in case of
short circuit events, isolates the line.
Speak to our Dubai Civil Defence approved team about supply, installation and maintenance.
WhatsApp Us +971 52 897 5406
Manual alarm call points are designed for the purpose of raising an alarm manually once verification of a..
View details
Intelligent addressable weather-proof sounders and sounder strobes are audible warning devices which are..
View details
The Addressable Fire Alarm Control Panel is an essential component of Guard Master Safety Systems LLC's..
View details
Guard Master Safety Systems LLC is dedicated to providing lifesaving services for smoke detectors that detect..
View details
The Fire Alarm Sounder with Flasher incorporates both the sounder and flasher into single versatile unit. It..
View details
Guard Master Safety Systems LLC provides services for smoke detectors with sounder bases, which deliver a..
View details
Guard Master Safety Systems LLC offers smoke detectors with sounders and flashers, providing a multi-sensory..
View details
Heat detectors are essential for ensuring peak efficiency in a building. Our Fire safety specialists evaluate..
View details
Our team of experts at Guard Master Safety Systems LLC makes sure that multisensor detectors are positioned..
View details
Guard Master Safety Systems LLC provides Weatherproof Manual Call Points for building safety, ensuring..
View details
Guard Master Safety Systems LLC provides fire alarm sounders that provide clear and forceful notifications..
View details
For improved fire safety, Guard Master Systems LLC provides Fire Alarm Flashers. In addition to providing..
View details
Guard Master Safety Systems LLC's Beam Detectors with Receivers are Invisible Walls of Protection. Protect..
View details
Guard Master Safety Systems, LLC Monitoring Module: Keep your eyes on the sky (or the wall). This unsung hero..
View details
Guard Master Safety Systems LLC Control Module possesses the same power as a skilled conductor conducting an..
View details
Guard Master Safety Systems LLC. Zone Control Module. Divide your fire system into zones to provide focused..
View details
Guard Master's Fire Proof Cable for Addressable Fire Alarm Systems offers robust fire safety in the UAE...
View details
Recurring false fire alarms in Dubai apartments? Use an incident log, a resident email template and repair checks to get building..
Read article
Starting a company in this space takes more than a trade license though. Dubai treats fire safety as a life safety matter, so the..
Read article
A conventional fire alarm system splits a building into zones. Each zone is a group of detectors and call points wired together..
Read articleTalk to our Dubai Civil Defence approved team about design, supply, installation, testing and annual maintenance.