Input Output Modules Supplier in Dubai - UAE

Input Output Modules


Monitor and control modules, offering high performance by the VIP communication protocol, can be configured to operate in cause-effect scenario and fire automation can be performed. Contact us to schedule a professional installation and free consultation!

  • Category : Fire Alarm Systems

Share:

  • Facebook Twitter LinkedIn WhatsApp Pinterest

Product Description


Monitor and control modules, offering high performance by the VIP communication protocol, can be configured to operate in cause-effect scenario and fire automation can be performed.

- Compatible with EN 54-17 and EN 54-18

- Optional short circuit isolator models

- LED-indicated activation, fault, and communication status

- Easy mounting with rail system

- 2/1 I/O module with 2 zone monitoring inputs 1 sounder output option or 2 dry contact monitoring inputs 1 dry contact relay output option

- 4/2 I/O module with 4 dry contact monitoring inputs 2 dry contact relay outputs option

 

Dry Contact Input / Output Modules

Modules are loop-powered and can be programmed to operate in cause-effect scenarios. External systems can be monitored by switch monitor inputs and can be controlled by relay outputs within fire automation.

Switch monitor inputs are used for monitoring external dry switch relay output. Switches have normally open and normally close operate features. In case of changing of switch position, event type that is detected by panels can be determined by users.

The module has one relay output with voltage-free, bipolar contact max. load of 30V DC, 1A . The relay can operate as normally open or normally close.

The models have SCI, internal short circuit isolator, in case of short circuit events, isolates the line.


Energy Input / Output Modules

Energy Input/Output needs 18V - 30V DC external power supply and that can be monitored in case of fault event and programmable for cause-effect scenarios.

Zone monitoring Inputs are used to monitor the conventional type detectors and manual call points. In case of change of Input status, events type that are detected by panel can be determined by users.

24V DC 500mA sounder output can be activated within fire automation as required. 24V DC 500mA sounder output can be arranged according to event type that is determined by users.

With SCI models, internal short circuit isolator, in case of short circuit events, isolates the line.

Related Product


Manual Call Points Supply and Installation in UAE
Manual Call Points
Weatherproof Sounders Supplier in UAE
Weatherproof Sounders
Addressable Fire Alarm Control Panel Supplier in UAE
Addressable Control Panel
Smoke Detectors Supply and Installation in UAE
Smoke Detectors
Fire Alarm Sounder with Flasher Supplier in UAE
Fire Alarm Sounder with Flasher
Smoke Detector with Sounder base Supplier in UAE
Smoke Detector with Sounder base
Smoke Detector with Sounder and Flasher Supplier in UAE
Smoke Detector with Sounder and Flasher
Heat Detector Supplier in Dubai - UAE
Heat Detector
Multi-sensor Detector Supply and Installation in UAE
Multisensor Detector
Weatherproof Manual Call Point Supplier in UAE
Weatherproof Manual Call Point
Sounder Supply and Installation in UAE
Sounder
Fire Alarm Flashers Supply and Installation in UAE
Fire Alarm Flashers
Beam Detector with Receiver in Dubai - UAE
Beam detector with Receiver
Monitoring Module Supply and Installation in Dubai - UAE
Monitoring Module
Control Module Fire Alarm System Supplier in UAE
Control Module
Zone Control Module Fire Alarm System in UAE
Zone Control Module
Fire Proof Cable for Fire Alarm System in UAE
Fire Proof Cable